Go back to datasheets

APTIV™ FILMS 1000

APTIV 1000 series films are the unfilled semi-crystalline films made from VICTREX™ PEEK polymer. The film provides a material solution for engineers in ultra-high performance applications.

APTIV films are a comprehensive range of versatile, high-performance films, the use of which can facilitate reduced systems costs, improved performance and enhanced design freedom.

APTIV 1000 has a unique combination of properties providing high temperature performance, light weight, mechanical strength, durability, excellent radiation, hydrolysis and chemical resistance, electrical insulation, wear and abrasion resistance, excellent barrier properties with high purity, good flammability without the use of flame retardants, low toxicity of combustion products, and low moisture absorption in a film format. Inherently halogen free and ease of processing makes APTIV films a technology enabler for our customers and end users.

Material Properties
Physical

Nominal Value

Unit

Test Method

Density (23°C)

1.30

g/cm³

ISO 1183

Water Absorption 1 (Equilibrium, 23°C, 0.0500 mm, 50% RH)

0.040

%

ISO 62

Shrinkage 2

MD : 200°C, 50.0 µm

< 0.50

%

TD : 200°C, 50.0 µm

< 0.50

%

Films

Nominal Value

Unit

Test Method

Film Thickness - Recommended / Available

8 to 750 µm

Tensile Modulus

ISO 527-3

MD : 23°C, 25 µm

2600

MPa

TD : 23°C, 25 µm

2800

MPa

MD : 23°C, 50 µm

2500

MPa

TD : 23°C, 50 µm

2500

MPa

MD : 23°C, 125 µm

2400

MPa

TD : 23°C, 125 µm

2300

MPa

MD : 23°C, 250 µm

2300

MPa

TD : 23°C, 250 µm

2300

MPa

Tensile Stress

ISO 527-3

MD : Break, 23°C, 25 µm

140

MPa

TD : Break, 23°C, 25 µm

120

MPa

MD : Break, 23°C, 50 µm

130

MPa

TD : Break, 23°C, 50 µm

120

MPa

MD : Break, 23°C, 125 µm

120

MPa

TD : Break, 23°C, 125 µm

120

MPa

MD : Break, 23°C, 250 µm

110

MPa

TD : Break, 23°C, 250 µm

110

MPa

Tensile Elongation

ISO 527-3

MD : Break, 23°C, 25 µm

> 150

%

TD : Break, 23°C, 25 µm

> 150

%

MD : Break, 23°C, 50 µm

> 150

%

TD : Break, 23°C, 50 µm

> 150

%

MD : Break, 23°C, 125 µm

> 150

%

TD : Break, 23°C, 125 µm

> 150

%

MD : Break, 23°C, 250 µm

> 150

%

TD : Break, 23°C, 250 µm

> 150

%

Trouser Tear Resistance 3

ISO 6383-1

MD : 50 µm

6.00

N/mm

TD : 50 µm

8.00

N/mm

Puncture Resistance (23°C, 50.0 µm)

26

kJ/m²

Internal Method
Thermal

Nominal Value

Unit

Test Method

CLTE - Flow 4 (0.0500 mm)

4.7E-5

cm/cm/°C

ASTM D696
Electrical

Nominal Value

Unit

Test Method

Volume Resistivity 5 (23°C, 50 µm)

4.0E+16

ohms·cm

ASTM D257

Dielectric Strength 6

ASTM D149

23°C, 25 µm

270

kV/mm

23°C, 50 µm

190

kV/mm

23°C, 125 µm

120

kV/mm

23°C, 250 µm

70

kV/mm

Dielectric Constant (23°C, 50 µm, 10 MHz)

3.5

ASTM D150

Dissipation Factor (23°C, 50 µm, 10 MHz)

2.0E-3

ASTM D150

Dielectric Breakdown

ASTM D149

23°C, 25.0 µm

6750

V

23°C, 50.0 µm

9500

V

23°C, 125.0 µm

15000

V

23°C, 250.0 µm

17500

V

Notes
124 hrs
2TM-VX-84
323°C
4below Tg
5100 V
60.25 inch electrode

Hi, do you have PEEK questions I can help with?