Go back to datasheets

APTIV™ FILMS 1103

APTIV 1100 series films are the mineral filled semi-crystalline films made from VICTREX™ PEEK polymer. The film provides a material solution for engineers in ultra-high performance applications.

APTIV films are a comprehensive range of versatile, high-performance films, the use of which can facilitate reduced systems costs, improved performance and enhanced design freedom.

APTIV 1100 has a unique combination of properties providing high temperature performance, mechanical strength, durability, excellent radiation, hydrolysis and chemical resistance, electrical insulation, excellent barrier properties with high purity, good flammability without the use of flame retardants, low toxicity of combustion products, and low moisture absorption in a film format. Inherently halogen free and ease of processing makes APTIV films a technology enabler for our customers and end users. APTIV 1100 series provides a higher modulus and lower coefficient of linear thermal expansion over the APTIV 1000 series.

Material Properties
Physical

Nominal Value

Unit

Test Method

Density (23°C)

1.54

g/cm³

ISO 1183

Water Absorption 1 (Equilibrium, 23°C, 0.0500 mm, 50% RH)

0.090

%

ISO 62

Shrinkage 2

MD : 200°C, 50.0 µm

< 0.50

%

TD : 200°C, 50.0 µm

< 0.50

%

Films

Nominal Value

Unit

Test Method

Film Thickness - Recommended / Available

12 to 125 µm

Tensile Modulus

ISO 527-3

MD : 23°C, 25 µm

5500

MPa

TD : 23°C, 25 µm

4500

MPa

MD : 23°C, 50 µm

5500

MPa

TD : 23°C, 50 µm

4500

MPa

MD : 23°C, 100 µm

5000

MPa

TD : 23°C, 100 µm

4500

MPa

Tensile Stress

ISO 527-3

MD : Break, 23°C, 25 µm

70.0

MPa

TD : Break, 23°C, 25 µm

70.0

MPa

MD : Break, 23°C, 50 µm

90.0

MPa

TD : Break, 23°C, 50 µm

90.0

MPa

MD : Break, 23°C, 100 µm

90.0

MPa

TD : Break, 23°C, 100 µm

90.0

MPa

Tensile Elongation

ISO 527-3

MD : Break, 23°C, 25 µm

> 10

%

TD : Break, 23°C, 25 µm

< 10

%

MD : Break, 23°C, 50 µm

> 10

%

TD : Break, 23°C, 50 µm

< 10

%

MD : Break, 23°C, 100 µm

> 5.0

%

TD : Break, 23°C, 100 µm

< 10

%

Trouser Tear Resistance 3

ISO 6383-1

MD : 50 µm

5.00

N/mm

TD : 50 µm

6.00

N/mm

Puncture Resistance (23°C, 50.0 µm)

4

kJ/m²

Internal Method
Thermal

Nominal Value

Unit

Test Method

CLTE - Flow 4 (0.0500 mm)

1.8E-5

cm/cm/°C

ASTM D696

Thermal Conductivity

ASTM E1461

-- 5

0.61

W/m/K

-- 6

1.3

W/m/K

Electrical

Nominal Value

Unit

Test Method

Volume Resistivity 7 (23°C, 50 µm)

1.0E+16

ohms·cm

ASTM D257

Dielectric Strength 8 (23°C, 50 µm)

200

kV/mm

ASTM D149

Dielectric Constant (23°C, 50 µm, 10 MHz)

3.5

ASTM D150

Dissipation Factor (23°C, 50 µm, 10 MHz)

1.0E-3

ASTM D150
Notes
124 hrs
2TM-VX-84
323°C
4below Tg
5Through Plane
6In-Plane
7100 V
80.25 inch electrode