Logotype victrex
ProdukteProdukte
Produkte Overview
PolymerePolymere
Polymere Overview
450G™ PEEK | Victrex
PEEK Polymere
LMPAEK Polymere
PEEK FormenPEEK Formen
PEEK Formen Overview
Composite Tape
Fasern & Filamente
Fasern & Filamente
Folien
PEEK FertigteilePEEK Fertigteile
PEEK Fertigteile Overview
Composite Lösungen
Zahnräder
Medizinproduktekomponenten
Rohrleitungslösungen
Industriezweige
LuftfahrtLuftfahrt
Luftfahrt Overview
Triebwerk
Innenausstattung
Struktur
EnergieEnergie
Energie Overview
Öl und Gas
Erneuerbare Energien
AutomobilAutomobil
Automobil Overview
Chassis
Lösungen für die E-Motor Plattform
Getriebe & Motor
IndustrieIndustrie
Industrie Overview
Lebensmittelkontakt
Industrieanlagen
Robotik & Automatisierung
ElektronikElektronik
Elektronik Overview
Unterhaltungselektronik
Haushaltsgeräte Technik
Halbleiter
MedizintechnikMedizintechnik
Medizintechnik Overview
Implantierbar
Nicht implantierbar
Ressourcen
BildungBildung
Bildung Overview
Technische Datenblätter
Technische Leitfäden
Webinare
Whitepaper
BildungBildung
Bildung Overview
Blog
Broschüren
Häufig gestellte Fragen
RegulatorischRegulatorisch
Regulatorisch Overview
Zertifizierungen
MSDB
Regulatorisch
Über uns
Über Victrex
Unsere Bestimmung
Liefersicherheit
Qualität
Nachhaltigkeit
Technische Kompetenz
Neuigkeiten & Veranstaltungen
Investoren
Karriere
Contact us
Contact us
DE
EN
JA
DE
KO
CN
Logotype victrex
Start
VICOTE™ COATINGS F817
Logo
SHAPING FUTURE PERFORMANCE™

Seit der Erfindung von PEEK vor über 40 Jahren hat Victrex immer wieder neue Polymere, Materialien und Lösungen auf PAEK-Basis entwickelt, die die Märkte verändert haben und weltweit in den härtesten Umgebungen Wirkung zeigen.

Wir bringen transformative Lösungen, die jeden Tag die Materialherausforderungen der Welt angehen.

Produkte
Polymere
  • PEEK Polymere
  • LMPAEK Polymere
PEEK-Teile
  • Composite Lösungen
  • Zahnradlösungen
  • Medizinproduktekomponenten
  • Rohrleitungslösungen
PEEK-Formen
  • Composite-Tapes
  • Folien
Branchen
  • Luftfahrt
  • Automobil
  • Elektronik
  • Energie
  • Industrie
  • Medizintechnik
Ressourcen
  • Blog
  • Broschüren
  • Häufig gestellte Fragen
  • Konformitätsbescheinigungen
  • Technische Datenblätter
  • Technische Leitfäden
  • Webinare
  • Whitepaper
Weiterführende Links
  • Über Victrex
  • Kontakt
  • Manage My Preferences
  • PFAS-freie PEEK Polymere
  • Allgemeine Bedingungen
  • Nutzungsbedingungen
  • Datenschutzrichtlinie
  • Cookie-Richtlinie
  • Erklärung zum Modern Slavery Act
  • Sitemap
  • victrexplc.com
  • invibio.com
© 2026 Copyright Victrex plc. Alle Rechte vorbehalten.
Go back to datasheets

VICOTE™ COATINGS F817

VICOTE F817 Enhanced Adhesion Grade
VICOTE is the brand name for the Victrex range of coatings based on VICTREX PEEK polymer. The VICOTE dispersions are available through Victrex plc or its preferred coater network. Contact Victrex plc for further details.

VICOTE dispersions are aqueous based, however there may be small amounts of solvent present. Refer to the appropriate MSDS sheet for details.

SUBSTRATES AND PREPARATION
VICOTE F817 can be applied to most ferrous and non-ferrous metals. Cast metals need to be de-gassed in an oven to prevent pin holes in the coating surface. Aluminium and other thermally sensitive substrates may be coated however the mechanical properties of the substrate may be affected when exposed to VICOTE processing temperatures.

The VICOTE F817 enhanced adhesion grade can be used on metal substrates where limited surface roughening is allowed or desired. When using this VICOTE grade the adhesion to a non-roughened or grit blasted surface is much higher than using the standard VICOTE dispersions. VICOTE F817 will withstand 24 hours boiling water test on non-grit blasted stainless steel without loss of adhesion.

Note: Although roughening the metal surface may not be required, removal of oils and greases must be undertaken to obtain the optimum adhesion. Rust and mill scale would need to be removed by conventional grit blasting while either thermal degreasing or a conventional vapour degreasing step should be employed to remove oils and greases. Once this is done the substrate should not be
handled with bare hands.

Note: Phosphate pretreated substrates are not recommended for VICOTE grades as the high processing temperatures required for processing can result in de-lamination of the coating.

SPRAYING
A conventional gravity fed spray gun with a nozzle size between 0.7 and 1.8mm has been found suitable for applying VICOTE dispersions. Edges of components should be sprayed first before applying a complete coating. An air pressure to the gun of between 35 and 50 psi has been found to be a suitable spray pressure. Spray at right angles to the substrate wherever possible. The spray gun
and cup can be cleaned with water after use.

PROCESSING
For general processing information consult the VICOTE dispersion coating guides. Coated parts should be dried in air for 10 minutes then dried in an oven for 10 minutes at 120°C before placing in an oven at 400°C to fuse and melt the coating.

By following the processing guide smooth coatings should be achievable. Because VICOTE Coatings are semicrystalline thermoplastics as with all these types of products some shrinkage will take place when the coating cools. Depending on the mass of the substrate, coating thickness and rate of cooling will determine the amount of shrinkage.

VICOTE F817 should result in crystalline coatings which should not require further post processing treatment.

STORAGE AND HANDLING CONSIDERATIONS
VICOTE drums should be stored in a clean dry environment and should not be stored with the lids removed as this may result in airborne dust contaminating the product, which could cause coating defects.

The VICOTE dispersions will soft settle after prolonged standing. They can be re-dispersed readily by stirring of the liquid suspension. The drums can also be rolled to agitate the dispersion and re-disperse. High shear dispersing should be avoided as the wetting agent is prone to shear thinning. Although it is recommended that the dispersion is not allowed to freeze, re-dispersing after thawing is possible. Optimum storage temperature is 5°C – 25°C.

VICOTE F817 is packed in 20 kg polythene UN drums enclosed
in a strong cardboard box with the VICOTE logo. The product has a shelf life of 12 months if kept in its original container with the lid securely fastened and ideally should not be used after this time.

SAFETY PRECAUTIONS
Before applying VICOTE dispersions, read the appropriate Material Safety Data Sheet (MSDS) and the processing guide, available from Victrex plc.

VICOTE F817 should be only applied using suitable exhaust ventilation. Care should be taken not to inhale fumes or vapours. The washing of hands and good housekeeping are a prerequisite before handling these products.

Request a quoteDownload PDF
Material Properties
Physical

Nominal Value

Unit

Test Method

Specific Gravity

1.150

g/cm³

ISO 2811

pH

10.0

Internal Method

Viscosity DIn 6 Cup (25°C)

30.0

sec

ISO 2431
Thermal

Nominal Value

Unit

Test Method

Glass Transition Temperature 1

ISO 11357-2

Onset

143

°C

Midpoint

147

°C

Melting Temperature 1

343

°C

ISO 11357-3
Additional Information

Nominal Value

Unit

Test Method

Adhesion 24 hour Boiling Water on non-grit blasted stainless steel 2

0

Internal Method

Conical Bend 3

Pass at 3.0

sec

Cross Hatch Adhesion Aluminum 2

0

ISO 2409

Cross Hatch Adhesion Mild Steel 2

0

ISO 2409

Cross Hatch Adhesion Stainless Steel 2

0

ISO 2409

Direct Impact Height

1 m

ISO 6272-1

Direct Impact Indentation depth

15 mm

ISO 6272-1

Direct Impact Weight

1 kg

ISO 6272-1

Konig Hardness 4 (40.0 to 50.0 µm)

118

sec

ISO 1522

Salt Spray degree of rusting

Ri/1

ISO 4628

Theory Volume Solids

28

%

Weight Solids

40

%

Internal Method

Typical Property Data for VICOTE F817 Coating on Film Thickness 25 - 30 µm

Notes
1Thermal analysis data of the PAEK polymer used in the VICOTE coating formulation
2Rating 0 to 5
3BS EN ISO 6860
4Minimum coating thickness required for this test was 30 µm